enen/ arar
Home Air Conditioner Production Line Equipment

System Precision Tester Designed For Air Conditioning Evaporators And Condensers

System Precision Tester Designed For Air Conditioning Evaporators And Condensers

The System Precision Tester, also known as a blockage detection device,  is designed to detect blockages during the welding production process of air conditioning evaporators, condensers, or pipeline components.

  • Item No :

    HH-JD-207
  • Order(MOQ) :

    1 set
  • Payment :

    T/T,L/C
  • Product Origin :

    China
  • Color :

    Customizable
  • Shipping Port :

    Guangzhou Port
  • Lead Time :

    45 working days
  • Price :

    Negotiatable

Product Introduction of System Precision Tester

Features:

Versatile Detection Modes: It can operate in either differential pressure mode or flow mode, providing flexibility in detecting blockages based on different system conditions.

Calibration and Analysis: The equipment detects pressure or flow in the system and compares it with standard samples for calibration. It then performs conversion analysis on the detected data to accurately determine if a product is blocked.

Multiple Interface Compatibility: It is equipped with various communication interfaces such as RS485/RS232/Modbus TCP/IP and a USB 2.0 interface, enabling easy connection and data transfer with other devices.

Main Parameters:

Test Pressure: 0.4 - 0.6Mpa

Power Supply: 220V/50Hz

Air Pressure Adjustment Mode: Mechanical Voltage Regulation

Differential Pressure Test Accuracy: 0.25%FS

Flow Test Accuracy: 0.25%FS

Flow Detection Range: Multiple ranges including 1, 0 - 10L/min; 2, 0 - 50L/min; 3, 1 - 100L/min; 4, 2 - 200L/min; 5, 6 - 600L/min

 

 

Main Performance:

High Accuracy: With a differential pressure test accuracy and flow test accuracy of 0.25%FS, it can provide precise detection of blockages in the system.

Wide Detection Range: The various flow detection ranges allow it to handle different flow conditions and detect blockages in a wide variety of systems.

Effective Blockage Detection: By comparing detected data with standard samples and performing analysis, it can effectively determine whether a product is blocked, ensuring the quality of the production process.

 

 

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.

Related Products

Dual-system Refrigerant Filling Machine HH-LJ-208
Dual-system Refrigerant Filling Machine HH-LJ-208

HH-LJ-208 series dual-system refrigerant filling machine, the left and right filling guns can be switched arbitrarily and used selectively. It is suitable for production operations of mixed production lines of more than two refrigerants, fully improving the production efficiency of the production line. It can be filled with conventional environmentally friendly refrigerants such as R134a, R407c, R22, R404A, R406A, R410A, etc. 

Details
High Speed Testing Safety Testing Machine
High Speed Testing Safety Testing Machine

The comprehensive electrical safety performance tester provides multiple combined testing functions, with high precision and high-speed testing, and can meet the testing requirements of many industries.

Details
Refrigerant Filling Machine Environmentally Friendly Refrigerants HH-LJ-204
Refrigerant Filling Machine Environmentally Friendly Refrigerants HH-LJ-204

HH-LJ-204 series refrigerant filling machine, the left and right filling guns can be switched arbitrarily and used selectively. It is suitable for production operations of mixed production lines of more than two refrigerants, fully improving the production efficiency of the production line. It can be filled with conventional environmentally friendly refrigerants such as R134a, R407c, R22, R404A, R406A, R410A, etc. 

Details
Single-gun refrigerant filling equipment
Explosion-proof Series Refrigerant Filling Machine HH-LJ-B20

HH-LJ-B20 series dual-system refrigerant filling machine, the left and right filling guns can be switched arbitrarily and used selectively. It is suitable for production operations of mixed production lines of more than two refrigerants, fully improving the production efficiency of the production line. It can be filled with conventional environmentally friendly refrigerants such as R134a, R407c, R22, R404A, R406A, R410A, etc. 

Details
Automated Production Air Conditioner Assembly Line
Automated Production Air Conditioner Assembly Line

The air conditioner assembly line is a facility that assembles various components of an air conditioner into the final product and is suitable for air conditioner manufacturers.

Details
Optimizing Refrigeration Performance Intelligent Refrigerant Boosting Station
Optimizing Refrigeration Performance Intelligent Refrigerant Boosting Station

The Refrigerant Booster Station is an efficient and safe auxiliary device for refrigeration equipment, specifically designed to boost pressure during refrigerant filling processes.

Details
Gas Monitoring Alarm Control Station
Gas Monitoring Alarm Control Station

Gas Monitoring Alarm Control Station is a crucial device for gas safety management. Its features of gas detection, ventilation control, and reliable alarm system, along with its reasonable parameters and good performance, make it an ideal choice for environments where gas safety is a concern. 

Details
Air Conditioner Testing Laboratory (Air Enthalpy Method)
Air Conditioner Testing Laboratory (Air Enthalpy Method)

The Air Conditioner Testing Laboratory (Air Enthalpy Method) is a specialized facility designed for testing the performance of air conditioners.

Details

leave a message

leave a message
If you are interested in our equipment and want to know more details, please leave a message here. we will contact you as soon as possible.
Submit

Our hours

Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)

Contact Us:hongce@iectester.com

Home

Products

whatsApp

contact