Emial Us :
hongce@iectester.comThe comprehensive electrical safety performance tester provides multiple combined testing functions, with high precision and high-speed testing, and can meet the testing requirements of many industries.
Item No :
HH-AZ-201Order(MOQ) :
1 setPayment :
T/T,L/CProduct Origin :
ChinaColor :
Customizable colorsShipping Port :
Guangzhou PortLead Time :
30 working daysPrice :
NegotiatableThe Safety Testing Machine is a versatile and comprehensive testing device designed to ensure the electrical safety and performance of various equipment and components. It offers a suite of test functions including AC Hi-pot, Insulation Resistance, Grounding Resistance, Leakage Current, No-load Power, and Low Voltage Start-up, all tailored to meet diverse safety assessment needs.
The AC Hi-pot test checks for electrical insulation strength by applying a high voltage AC signal, while Insulation Resistance measures the resistance of insulating materials to leakage currents under DC voltage. The Grounding Resistance test assesses the effectiveness of grounding connections, ensuring safe dissipation of electrical currents.
The Leakage Current test evaluates the electric leakage under specified conditions, differentiating between dynamic and static leakage types. The No-load Power test measures active power consumption without a load, providing insights into energy efficiency. The Low Voltage Start-up test verifies the equipment's ability to start under reduced voltage conditions.
The machine boasts high precision and accuracy in its measurements, with adjustable settings and alarm functions to monitor and ensure compliance with safety standards. It features a user-friendly interface and offers flexible communication options, including RS232 and optional interfaces like RS485, CAN, and TCP/IP, facilitating integration into automated testing systems.
External control modes, such as PLC interface and switching value signals, enhance the machine's versatility for various testing scenarios. The robust design, complete with standard accessories like power cords, foot switches, testing pliers, and a testing box, ensures ease of use and comprehensive testing capabilities.
With its comprehensive test functions, precise measurements, and adaptable configurations, this Safety Testing Machine stands as a reliable solution for ensuring the electrical safety and reliability of a wide range of devices and systems.
Provides Multiple Test Functions: AC Hi-pot、Insulation Resistance、Grounding Resistance、Leakage Current、No-load Power、Low Voltage Start-up |
|
AC Hi-pot |
|
Output voltage setting range/precision |
AC 100~5000V ±(1.5%×setting value+5 words) static |
Breakdown current |
0.100~100.00mA ±(1.5%×display value+5 words) |
Breakdown current preset alarm |
Max.: 0.10~99.99mA; Min.: 0.00~99.99mA |
Test time range/resolution |
0,0.5~999.9s 0.1s/step |
Arc detection(optional) |
1~9 level(9 is the most sensitive level) |
Insulation resistance |
|
Output voltage setting |
DC 100~1250V ±(1.5%×reading+5 words) |
Insulation resistance |
1~2000MΩ ≤100MΩ:±(5%×display value+3 words); >100 MΩ: |
Insulation resistance |
Max.: 0~2000MΩ; Min.: 1~2000MΩ |
Test time |
0,0.5~999.9s 0.1s/step |
Grounding resistance |
|
Grounding current |
2.0~32.0A ±(1.5%×setting value+5 words) |
Grounding resistance |
10~600mΩ ±(1.5%×display value+5 words) |
Grounding resistance |
Max.: 5~10A:10~600mΩ;11~25A:10~300mΩ;26~32A:10~ |
Test time |
0,0.5~999.9s 0.1s/step |
Leakage current |
|
Output voltage |
1.06 times rated voltage, built-in variable frequency power |
Leakage type setting |
Dynamic leakage, static leakage, optional equipped with 3 types of body network, which can be |
Output voltage setting range/precision |
5.0-280.0V ±(0.5%×display value+2 words) |
Leakage current setting range/precision |
0.050~20.00mA ±1.5%×display value+10uA) |
Leakage current setting alarm range |
Max.: 0.050~20.00mA; Min.: 0.000~20.00mA |
Test time range/resolution |
0,0.5~999.9s 0.1s/step |
No-load power |
|
Output voltage |
1.0 times rated voltage, built-in variable frequency power |
Output voltage measurement range/precision |
AC 5.0~280.0V ±(0.5%×display value+2 words) |
Output current measurement |
AC 0.20~30.00A ±(0.5%×display value+2 words) |
Active power measurement |
10.0~6000W ±(0.5%×display value+5 words) |
Power setting alarm range |
Max.: 10.0~6000W ; Min.: 0.0~6000W |
Test time range/resolution |
0,0.5~999.9s 0.1s/step |
Low voltage start-up |
|
Output voltage |
0.85 times rated voltage, built-in variable frequency power |
Output voltage measurement range/precision |
5.0-280.0V ±(0.5%×display value+2 words) |
Start-up current measurement range/precision |
AC 0.20~30.00A ±(0.5%×display value+2 words) |
Current setting alarm range |
Max.: 0.20~30.00A ; Min.: 0.00~30.00A |
Test time range |
0,0.5~999.9s 0.1s/step |
accessories |
|
Communication Interface |
RS232,Optional(RS485,CAN,TCP/IP ) |
External Control mode |
PLC interface,Switching value signal |
size(W×H×D),mm |
600×1840×600 The height includes reels and alarm light. |
Standard accessories |
Power cord×1、foot switch×1 、32Atesting pliers×1、testing box |
Our hours