Emial Us :
hongce@iectester.comHH-LJ-B20 series dual-system refrigerant filling machine, the left and right filling guns can be switched arbitrarily and used selectively. It is suitable for production operations of mixed production lines of more than two refrigerants, fully improving the production efficiency of the production line. It can be filled with conventional environmentally friendly refrigerants such as R134a, R407c, R22, R404A, R406A, R410A, etc.
Item No :
HH-LJ-B20Order(MOQ) :
1 setPayment :
T/T,L/CProduct Origin :
ChinaColor :
Customizable colorsShipping Port :
Guangzhou PortLead Time :
90 working daysPrice :
NegotiatableProduct introduction:
This Explosion-proof Series Refrigerant Filling Machine is suitable for refrigerant filling of various refrigeration appliances such as freezers, refrigerators, display cabinets, household air conditioners, ice machines, water dispensers, heat pipes, heat pumps, floor heating, etc. The machine has strict vacuum detection and leakage detection functions, and the automatic filling key operation fully improves the filling quality and production efficiency. For refrigeration products produced in mixed lines, this machine is equipped with up to 100 channels, and different filling doses can be set according to needs. It is also equipped with a humanized barcode reader for convenience, and users can automatically fill the type through the barcode. The equipment also has self-monitoring and fault diagnosis functions to help users find and solve problems early.
Application areas:
Explosion-proof refrigerant filling machines are widely used in refrigeration equipment manufacturing, automobile air conditioning maintenance, home appliance repair and chemical industry.
Refrigeration equipment manufacturing: In the process of producing various refrigeration products such as water dispensers, refrigerators and air conditioners, explosion-proof refrigerant filling machines can set different filling doses according to the needs of different products through their design of up to 100 channels. This flexibility ensures maximum production efficiency and stable product quality.
Automobile air conditioning maintenance: Explosion-proof refrigerant filling machines also play an important role in the maintenance of automobile air conditioning systems. Since automobile air conditioning systems usually use flammable and explosive refrigerants such as R134a, it is necessary to use equipment with ATEX explosion-proof certification for filling and recycling. This not only ensures the safety of operators, but also complies with relevant safety standards and regulatory requirements.
Home appliance repair: In the field of home appliance repair, especially when it comes to the repair of refrigeration equipment, explosion-proof refrigerant filling machines provide a safe and reliable solution. For example, when repairing a household refrigerator or air conditioner, technicians need to accurately control the amount of refrigerant to ensure the efficiency and economy of the equipment operation. The humanized design and high-precision control system of the explosion-proof refrigerant filling machine make this process easier and safer.
Chemical industry: In the process of handling flammable and explosive chemicals, the explosion-proof refrigerant filling machine also shows its irreplaceable value. Especially in those scenarios where rapid recovery and filling of multiple hydrocarbon refrigerants are required, such as using R290, R600a, R1234yf, etc., the application of these equipment not only improves operating efficiency, but also greatly reduces potential safety risks.
Technical parameters:
Optional equipment models |
HH-LJ-B204 |
HH-LJ-B208 |
HH-LJ-B208T |
Charge the media |
R600a、R290、R32、R1234yf Other hydrocarbon environmentally friendly refrigerants |
||
Charge quantity range |
10-499g |
10-1999g |
10-1999g |
Charging speed |
50-80g/s |
50-80g/s |
150-220g/s |
Charging precision |
within 100g<±0.5g, 100g above<±0.5% |
||
Measurement method |
VES Precision flowmeter standard, RHEONIK mass flowmeter optional |
||
Flow resolution |
0.1g |
0.1g |
0.1g |
vacuum speed |
4L/s |
8L/s |
8L/s |
Vacuum degree of this machine |
≤5Pa |
≤5Pa |
≤5Pa |
Detection of vacuum degree |
3Pa-300Pa |
3Pa-300Pa |
3Pa-300Pa |
Channel number |
100pcs |
100pcs |
100pcs |
Refrigerant pressure of work |
1.8-2.5 MPa |
1.8-2.5 MPa |
1.8-2.5 MPa |
The compressed air supply pressure |
0.5-0.7MPa |
0.5-0.7MPa |
0.5-0.7MPa |
PLC、 HMI、Admodule |
Mitsubishi/Siemens |
||
Voltage & Power |
AC380V 50Hz /1.2kw |
AC380V 50Hz /1.5kw |
AC380V 50Hz /1.5kw |
Injector and quick connector |
1/4"(3/8") |
||
Barcode reading function |
symbol |
||
Communication interface |
RS485/RS232/Ethernet |
||
Apply product category |
Refrigerant filling of refrigerators, refrigerators, display cabinets, household air conditioners, ice makerswater dispensers, heat pipes, heat pumps, foor heating and other refrigeration appliances |
||
Special requirements |
Special configuration and technical requirements,in addition to discuss |
Product details:
Refrigerant filling gun
FAQ:
Q1: What is the explosion-proof grade of the explosion-proof refrigerant filling machine?
A: Our explosion-proof refrigerant filling machines usually have a higher explosion-proof grade, and the specific grade varies according to different models. Generally speaking, common explosion-proof grades can meet the use requirements of most flammable and explosive environments. For example, Exd [specific explosion-proof grade] can effectively prevent explosion accidents caused by electrical sparks in hazardous environments.
Q2: What is the filling accuracy?
A: Our equipment has high-precision filling performance. The filling amount of refrigerant can be accurately controlled, and the error is usually within ± [specific error value]. This ensures that the refrigeration system can obtain the accurate amount of refrigerant, thereby ensuring the stability and reliability of the refrigeration effect.
Q3: What types of refrigerants can be filled?
A: The explosion-proof refrigerant filling machine can be filled with a variety of refrigerants, including but not limited to common conventional refrigerants such as R134a, R410A, and some flammable and explosive refrigerants such as R290, R600a, etc. For different types of refrigerants, the equipment will have corresponding parameter settings and safety measures to ensure the safety and accuracy of the filling process.
Q4: What issues should be paid attention to in the maintenance of the equipment?
A: Maintenance is essential to ensure the performance and safety of the equipment. First of all, the electrical system, seals, pipelines and other components of the equipment should be checked regularly to ensure that they are intact. Secondly, the filters, lubricating oil and other wearing parts should be replaced at the prescribed time intervals. In addition, during use, pay attention to keep the equipment clean and avoid dust, oil and other impurities from entering the equipment. If you encounter a malfunction or abnormal situation, you should stop using it in time and contact professional technicians for repair.
Q5: What does after-sales service include?
A: We provide comprehensive after-sales service, including equipment installation and commissioning, training guidance, free repair and maintenance during the warranty period, long-term technical support, etc. During the warranty period, if the equipment fails, we will respond in time and arrange professional technicians to repair it. Outside the warranty period, we will also provide users with maintenance services and accessories at a reasonable price.
Our hours
Mon 11/21 - Wed 11/23: 9 AM - 8 PM
Thu 11/24: closed - Happy Thanksgiving!
Fri 11/25: 8 AM - 10 PM
Sat 11/26 - Sun 11/27: 10 AM - 9 PM
(all hours are Eastern Time)